TY - JOUR
T1 - A study on the matching of constraint between steam turbine blade and laboratory specimens
AU - Yang, Jie
AU - Liu, Yuman
AU - Chen, Haofeng
PY - 2020/5/1
Y1 - 2020/5/1
N2 - The matching of constraint between laboratory specimens and actual cracked structures is a key problem of the accurate structure integrity assessment. Different laboratory specimens and the steam turbine blade with different constraints were selected, the matching of constraint between steam turbine blade and laboratory specimens was investigated. The results shown that the steam turbine blade with 2c = 50 mm, a/2c = 0.20 has a matching constraint with single edge-notched bend specimen with a/W = 0.6 and single edge-notched tensile specimen with a/W = 0.3. The steam turbine blade with 2c = 50 mm, a/2c = 0.25 has a matching constraint with single edge-notched bend specimen with a/W = 0.7. The steam turbine blade with 2c = 50 mm, a/2c = 0.30 has a matching constraint with single edge-notched bend specimen with a/W = 0.5 and single edge-notched tensile specimen with a/W = 0.1. The steam turbine blade with 2c = 50 mm, a/2c = 0.35 has a matching constraint with single edge-notched bend specimen with a/W = 0.4, compact tension specimen with a/W = 0.3 and central-cracked tension specimen with a/W = 0.7. The steam turbine blade with a = 15 mm, a/2c = 0.30 has a matching constraint with compact tension specimen with a/W = 0.7 and single edge-notched tensile specimen with a/W = 0.5. The steam turbine blade with a = 15 mm, a/2c = 0.40 has a matching constraint with compact tension specimen with a/W = 0.4. The steam turbine blade with a = 15 mm, a/2c = 0.50 has a matching constraint with single edge-notched bend specimen with a/W = 0.5.
AB - The matching of constraint between laboratory specimens and actual cracked structures is a key problem of the accurate structure integrity assessment. Different laboratory specimens and the steam turbine blade with different constraints were selected, the matching of constraint between steam turbine blade and laboratory specimens was investigated. The results shown that the steam turbine blade with 2c = 50 mm, a/2c = 0.20 has a matching constraint with single edge-notched bend specimen with a/W = 0.6 and single edge-notched tensile specimen with a/W = 0.3. The steam turbine blade with 2c = 50 mm, a/2c = 0.25 has a matching constraint with single edge-notched bend specimen with a/W = 0.7. The steam turbine blade with 2c = 50 mm, a/2c = 0.30 has a matching constraint with single edge-notched bend specimen with a/W = 0.5 and single edge-notched tensile specimen with a/W = 0.1. The steam turbine blade with 2c = 50 mm, a/2c = 0.35 has a matching constraint with single edge-notched bend specimen with a/W = 0.4, compact tension specimen with a/W = 0.3 and central-cracked tension specimen with a/W = 0.7. The steam turbine blade with a = 15 mm, a/2c = 0.30 has a matching constraint with compact tension specimen with a/W = 0.7 and single edge-notched tensile specimen with a/W = 0.5. The steam turbine blade with a = 15 mm, a/2c = 0.40 has a matching constraint with compact tension specimen with a/W = 0.4. The steam turbine blade with a = 15 mm, a/2c = 0.50 has a matching constraint with single edge-notched bend specimen with a/W = 0.5.
KW - constraint
KW - laboratory specimen
KW - matching
KW - steam turbine blade
KW - structure integrity assessment
UR - http://www.scopus.com/inward/record.url?scp=85084733861&partnerID=8YFLogxK
U2 - 10.1177/1687814020922007
DO - 10.1177/1687814020922007
M3 - Article
AN - SCOPUS:85084733861
VL - 12
SP - 1
EP - 11
JO - Advances in Mechanical Engineering
JF - Advances in Mechanical Engineering
SN - 1687-8132
IS - 5
ER -