TY - JOUR
T1 - Calibration-free in-line monitoring of pellet coating processes via optical coherence tomography
AU - Markl, Daniel
AU - Zettl, Manuel
AU - Hannesschläger, Günther
AU - Sacher, Stephan
AU - Leitner, Michael
AU - Buchsbaum, Andreas
AU - Khinast, Johannes G.
PY - 2015/3/24
Y1 - 2015/3/24
N2 - The paper presents a new in-line measurement technique for determining the coating thickness and uniformity of pharmaceutical pellets during film-coating in a fluid-bed apparatus. Non-destructive and contact-free process monitoring was performed via an optical coherence tomography (OCT) sensor providing cross-section images. Through the OCT measurements, the coating thickness could be determined directly, without a chemometric calibration model required for the quantification. The direct integration of the OCT sensor head into the fluid-bed systems allowed continuous monitoring of the coating growth. Moreover, the in-line investigation of the intra- and inter-pellet coating uniformity was possible due to OCT's high acquisition rate. Results of the in-line OCT measurements were validated using both off-line OCT images and particle size analysis by performing an image analysis of samples that were periodically removed from the process during the production. Three batches were produced under the same process conditions demonstrating the reproducibility of the results. Rather than providing the temporal and spatial average of a large number of pellets, the OCT sensor characterized local pellet properties of up to 130 individual pellets per minute. Therefore, the OCT technology allows the operator to directly monitor the coating thickness and uniformity in sub-micron resolution, which makes it a promising in-line PAT method.
AB - The paper presents a new in-line measurement technique for determining the coating thickness and uniformity of pharmaceutical pellets during film-coating in a fluid-bed apparatus. Non-destructive and contact-free process monitoring was performed via an optical coherence tomography (OCT) sensor providing cross-section images. Through the OCT measurements, the coating thickness could be determined directly, without a chemometric calibration model required for the quantification. The direct integration of the OCT sensor head into the fluid-bed systems allowed continuous monitoring of the coating growth. Moreover, the in-line investigation of the intra- and inter-pellet coating uniformity was possible due to OCT's high acquisition rate. Results of the in-line OCT measurements were validated using both off-line OCT images and particle size analysis by performing an image analysis of samples that were periodically removed from the process during the production. Three batches were produced under the same process conditions demonstrating the reproducibility of the results. Rather than providing the temporal and spatial average of a large number of pellets, the OCT sensor characterized local pellet properties of up to 130 individual pellets per minute. Therefore, the OCT technology allows the operator to directly monitor the coating thickness and uniformity in sub-micron resolution, which makes it a promising in-line PAT method.
KW - in-line quality control
KW - optical coherence tomography
KW - pharmaceutical film-coated pellets
KW - process analytical technology
UR - http://www.scopus.com/inward/record.url?scp=85028130329&partnerID=8YFLogxK
U2 - 10.1016/j.ces.2014.05.049
DO - 10.1016/j.ces.2014.05.049
M3 - Article
AN - SCOPUS:85028130329
VL - 125
SP - 200
EP - 208
JO - Chemical Engineering Science
JF - Chemical Engineering Science
SN - 0009-2509
ER -